Low Force Dynamic and Fatigue Testing of Orthopaedic Micro-Implants for Fracture Fixation

Standard

  • ASTM F543
  • ASTM E8

Specimen

  • Bone Screw
  • Medical Part
  • Implant

Materials

  • Metals
  • Biomedical
  • Biomaterials

Business Sector

  • Academic
  • Biomedical/Medical/Healthcare
  • Contract Testing Services

Test Types

  • Compression
  • Flexure
  • Simple Cyclic
  • Tension
Contact UsRequest an Accessory Catalog
  • Description
  • Literature
  • Contact Us

Orthopaedic micro-implants are used in Medicine and Dentistry to treat bone disease and fractures, and soft tissue injuries. It is crucial that the implants are robust and secure enough to maintain structural rigidity and alignment of bone or soft tissue during the healing process. During normal patient activity, implants can be subjected to high in vivo loading, which may result in catastrophic failure. Therefore, tests simulating loading conditions are critical to assess the expected performance over a specific period time or loading profile typically following ASTM, ISO, and FDA guidelines.

Cyclic fatigue tests have been successfully carried out on titanium finger micro-implants using our ElectroPuls™ E1000 and E3000 systems. We performed fatigue tests with a low-capacity Dynacell load cell mounted to the upper actuator with a small bolt and nut assembly used as the loading head. We used a metallice vice for the lower fixture.

We first performed the test in Digital Position Control to ensure stability. We then ran the tests in load control at 5, 10, 15 and 20Hz. We found that the control was very stable and peaks were well controlled with an accuracy of ±0.1N.

All of the testing was performed using the default loop control gains derived from the standard stiffness tuning. Using a combination of this tuning and Amplitude Control, the response was reasonable to achieve the amplitudes demanded and maintain the control stability.Within the ElectroPuls controller, it is possible to further adjust the control loop to improve turn-around and response. The optimization involves adjusting a single proportional term, Gain Factor, to add more loop gain.

In summary, the ElectroPuls dynamic systems achieve exceptional response and accuracy across a wide frequency range and are ideal for durability testing of implants. Using hardware features, such as inertia compensation from the Dynacell load cell, you can optimize the system response in or out of an environmental bath. These characteristics allow laboratories to investigate a comprehensive range of implant characteristics and performance.

ElectroPuls™ Electrodynamic Test Instruments

ElectroPuls instruments are state-of-the-art electrodynamic test systems for dynamic and static tests on materials & components. Powered entirely from a single-phase mains supply, they feature the latest in testing technology and a host of other user-oriented features.

  • Products
  • 4/24/2013
  • 1.7 MB

Your Email Address

Please enter your email address. Email addresses must contain the @ symbol. Email addresses can only contain letters, numbers and the following special characters: . ! # $ % & ' * + - / = ? ^ _ ` { | } ~ Email address domains can only contain letters, numbers, dots (.) and hyphens (-).

Your Message

Please enter your message. Email addresses can only contain letters, numbers and the following special characters: . ! # $ % & ' * + - / = ? ^ _ ` { | } ~
Next Checking to see if you are a returning visitor…

Welcome back!

Your Contact Information

Please enter your first name.
Please enter your last name.
Please select your country.
Please enter your company.
Please enter your address.
Please enter your address line 2.
Please enter your address line 3.
Please enter your county.
Please enter your city.
Please select your state/province.
Please enter your ZIP/Postal Code.
Please enter your telephone number.

Please confirm that you agree with our privacy and cookies policy to submit this form.

I agree to the terms & conditions of Instron's Privacy and Cookies Policy.

Subscribe to Instron News!
Check this box to receive pertinent commercial email from Instron focusing on products, upcoming events, and more!

Please choose a subscription option One or more required fields are empty, complete the form to continue. One or more fields contain formatting errors, fix the errors to continue. You must agree to Instron's Privacy Policy in order to continue.
Instron Logo

“It is our objective at Instron to provide our customers the best ownership experience by delivering the highest quality products, expert support and world-class service.”


Yahya Gharagozlou
Group President, ITW Test & Measurement

Useful Links

  • Careers
  • Newsletters
  • Case Studies
  • Literature Library
  • Glossary
  • Accreditation
  • Testing Systems
  • Accessories
  • Testing Solutions
  • Events
  • Webinars

Connect with Us

  • Blog
  • LinkedIn
  • YouTube
  • Slideshare
  • Facebook
  • Twitter

Sign Up For Our Newsletter

3C, PM Tower, 37 Greams Road, Chennai 600 006, Tamil Nadu, India | Sales: +91 44 2829 3888

© Illinois Tool Works Inc. All rights reserved. | web@instron.com

  • Privacy and Cookies Policy
  • Terms of Use
  • Export Control

Region Selector

Dismiss Region Selector

Americas

  • North America
  • Brasil
  • South America

All Other Countries

  • Global Site

Europe

  • France
  • Sweden
  • Deutschland
  • Hungary
  • Italia
  • Polska
  • Россия
  • España
  • Switzerland Deutsch | French | Italian
  • Türkçe
  • United Kingdom

Asia Pacific

  • Australia
  • 中国
  • India
  • 日本
  • 대한민국
  • Singapore
  • 台灣
  • ประเทศไทย